Automation Overview
1-Wire Network
Gadgets
HomeVision
  -
  -
  - Specifications
  - X-10
Lighting
PLC (AB SLC-500)
 
 
 

 

 
 

 

HomeVision Pro - Specifications

Information downloaded from the Custom Solutions web page.

Feature Specification
# of flags, variables, timers, scheduled events, periodic events, IR signals, and macros 255 each
Maximum schedule length 8000 (or more) lines
Data log size 64K bytes
TV event log size 256 lines
Port A (8 relays) ratings Single-Pole-Double-Throw (SPDT) power relays for 10Amps at 125VAC, 6Amps at 277VAC, and 5Amps at 100VDC
Port B (8 digital inputs) ratings +/-30VDC, pulled-up via resistor (which can be disabled with switches)
Port C (8-input configuration) ratings 0 to 5VDC, pulled-up
Port C (8-output configuration) ratings 0 and 5VDC at 20mA
System status LEDs 43
Video output Color NTSC video standard (PAL video on international units)
Serial ports Three ports.  One supports RS-232 only.  The other two support RS-232, RS-485 half-duplex (two-wire mode), and RS-485 full-duplex (four-wire mode).  All support baud rates of 300, 600, 1200, 2400, 4800, 9600, 19200 and 57600.  All use standard communication settings of 8 data bits, 1 start bit, 1 stop bit, and no parity.
USB port One. When used, one of the serial ports is not available.
Analog inputs (4) 0 to 5 VDC, 8-bit resolution
Digital temperature sensor interface Up to 64 sensors can be connected to the same three wires. Each sensor has it's own unique address so it can be individually read. Temperature range of -50 to +205 degrees F. 1 degree F resolution. 15 sensors can be automatically read per second.
Dimensions 14" x 13 x 3"
Required power source 12VDC, 1.2Amps.  2.1mm plug with center positive
Maximum number of Multifunction Expansion Boards 2
PC operating system Windows 3.1, 3.11, 95, 98, 2000, NT, or XP
Recommended PC 486, 90MHz, 32M Bytes RAM, VGA monitor or better, hard disk with 6M Bytes free, one serial port or USB port.

 

 

 

mailto: Webmaster